<title><![CDATA[Air Body Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Air-Body-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:59:31  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Air Body Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Air-Body-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:59:06  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Air Body Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Air-Body-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:58:46  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Bathroom Body Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Bathroom-Body-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:58:24  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Bathroom Body Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Bathroom-Body-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:57:58  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Bathroom Body Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Bathroom-Body-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:57:36  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Body Dryers YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Body-Dryers-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:57:08  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Body Dryers YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Body-Dryers-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:56:47  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Body Dryers YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Body-Dryers-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:56:26  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Body Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Body-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:56:01  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Body Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Body-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:55:35  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Body Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Body-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:55:14  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Stands YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Stands-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:54:43  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Stands YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Stands-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:54:20  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Stands YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Stands-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:53:57  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Commercial Hair Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Commercial-Hair-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:53:27  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Commercial Hair Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Commercial-Hair-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:53:03  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Commercial Hair Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Commercial-Hair-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:52:39  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Storage YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Storage-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:51:53  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Storage YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Storage-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:51:29  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Storage YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Storage-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:51:07  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[European Hair Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/European-Hair-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:50:34  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[European Hair Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/European-Hair-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:50:10  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[European Hair Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/European-Hair-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:49:47  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Dryer Hair Infinity YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Dryer-Hair-Infinity-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:46:10  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Dryer Hair Infinity YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Dryer-Hair-Infinity-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:45:46  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Dryer Hair Infinity YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Dryer-Hair-Infinity-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:45:17  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Wall Hair Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Wall-Hair-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:44:48  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Wall Hair Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Wall-Hair-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:44:26  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Wall Hair Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Wall-Hair-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:44:01  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Best Hair Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Best-Hair-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:42:11  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Best Hair Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Best-Hair-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:41:45  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Best Hair Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Best-Hair-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:41:23  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Portable Hair Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Portable-Hair-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:40:21  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. <BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG></TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;Safety timer automatically shuts off after 10 minutes.</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width="24%" bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width="54%" bgColor=#f9f9f9>&nbsp;220V~50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Current:</TD>
<TD bgColor=#f9f9f9>&nbsp;4.5A </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Power :</TD>
<TD bgColor=#f9f9f9>&nbsp;1000W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed :</TD>
<TD bgColor=#f9f9f9>&nbsp;13.5-14m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover :</TD>
<TD bgColor=#f9f9f9>&nbsp;Plastic</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size(mm) : </TD>
<TD bgColor=#f9f9f9>&nbsp;250x185x100</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Pcs/carton:</TD>
<TD bgColor=#f9f9f9>&nbsp;6pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;500x430x370</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Shaver socket:</TD>
<TD bgColor=#f9f9f9>&nbsp;Have 220VAC and 110V AC</TD></TR></TBODY></TABLE><BR>
<P>We are Specialized in manufacturing and exporting sanitary ware series</P>]]></description>
</item>
<item>
<title><![CDATA[Portable Hair Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Portable Hair Dryer YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:40:00  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG></TD>
<TD bgColor=#eeeeee colSpan=2>
<P align=left>&nbsp;Safety timer automatically shuts off after 10 minutes.</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD width="24%" bgColor=#f9f9f9>
<P align=left>&nbsp;Voltage:</P></TD>
<TD width="54%" bgColor=#f9f9f9>
<P align=left>&nbsp;220V~50Hz</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Current:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;4.5A </P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Power :</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;1000W</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Wind Speed :</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;13.5-14m/s</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Body cover :</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Plastic</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Size(mm) : </P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;250x185x100</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Pcs/carton:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;6pcs</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Meas:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;500x430x370</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Shaver socket:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Only 220V AC</P></TD></TR></TBODY></TABLE><BR>
<P>We are Specialized in manufacturing and exporting sanitary ware series</P>]]></description>
</item>
<item>
<title><![CDATA[Portable Hair Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Portable-Hair-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:39:35  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG></TD>
<TD bgColor=#eeeeee colSpan=2>
<P align=left>&nbsp;Safety timer automatically shuts off after 10 minutes.</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD width="24%" bgColor=#f9f9f9>
<P align=left>&nbsp;Voltage:</P></TD>
<TD width="54%" bgColor=#f9f9f9>
<P align=left>&nbsp;220V~50Hz</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Current:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;4.5A </P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Power :</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;1000W</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Wind Speed :</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;13.5-14m/s</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Body cover :</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Plastic</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Size(mm) : </P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;250x185x100</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Pcs/carton:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;6pcs</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Meas:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;500x430x370</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Shaver socket:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;no</P></TD></TR></TBODY></TABLE><BR>
<P>We are Specialized in manufacturing and exporting sanitary ware series</P>]]></description>
</item>
<item>
<title><![CDATA[Professional Hair Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Professional-Hair-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:39:05  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Professional Hair Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Professional-Hair-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:38:39  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Professional Hair Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Professional-Hair-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:38:15  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Wall Mounted Hair Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Wall-Mounted-Hair-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:37:45  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Wall Mounted Hair Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Wall-Mounted-Hair-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:37:24  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Wall Mounted Hair Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Wall-Mounted-Hair-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:36:42  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Holder YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Holder-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:36:03  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Holder YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Holder-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:35:40  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Holder YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Holder-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:35:12  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Stand YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Stand-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:34:44  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Stand YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Stand-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:34:17  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG></TD>
<TD bgColor=#eeeeee colSpan=2>
<P align=left>&nbsp;Safety timer automatically shuts off after 10 minutes.</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD width="24%" bgColor=#f9f9f9>
<P align=left>&nbsp;Voltage:</P></TD>
<TD width="54%" bgColor=#f9f9f9>
<P align=left>&nbsp;220V~50Hz</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Current:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;4.5A </P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Power :</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;1000W</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Wind Speed :</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;13.5-14m/s</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Body cover :</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Plastic</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Size(mm) : </P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;250x185x100</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Pcs/carton:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;6pcs</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Meas:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;500x430x370</P></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>
<P align=left>&nbsp;</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Shaver socket:</P></TD>
<TD bgColor=#f9f9f9>
<P align=left>&nbsp;Only 220V AC</P></TD></TR></TBODY></TABLE><BR>
<P>We are Specialized in manufacturing and exporting sanitary ware series</P>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer Stand YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-Stand-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:33:55  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer YD-750-3]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-YD-750-3.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:33:26  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on. 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;Safety timer automatically shuts off after 10 minutes.</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="24%" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="54%" bgcolor="#F9F9F9">&nbsp;220V~50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Current:</td> 
    <td bgcolor="#F9F9F9">&nbsp;4.5A </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Power :</td> 
    <td bgcolor="#F9F9F9">&nbsp;1000W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed :</td> 
    <td bgcolor="#F9F9F9">&nbsp;13.5-14m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover :</td> 
    <td bgcolor="#F9F9F9">&nbsp;Plastic</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size(mm) : </td> 
    <td bgcolor="#F9F9F9">&nbsp;250x185x100</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Pcs/carton:</td> 
    <td bgcolor="#F9F9F9">&nbsp;6pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;500x430x370</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Shaver socket:</td> 
    <td bgcolor="#F9F9F9">&nbsp;Have 220VAC and 110V AC</td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer YD-750-2]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-YD-750-2.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:32:57  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Only 220V AC</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Hair Dryer YD-750-1]]></title>
<link><![CDATA[http://www.handdryer.cc/Hair-Dryer-YD-750-1.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:32:10  GMT</PubDate>
<description><![CDATA[<P>This hair dryer is a wall-mounted unit that isolates electrical components from accidental water contact. It automatically activates when hand picec is removed from base and deactivates when replaced. The hose and hand picec are insulated to prevent heat build-up.Recommended for hotels,hospital and so on.</P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong></td> 
    <td colspan="2" bgcolor="#EEEEEE"><p align="left">&nbsp;Safety timer automatically shuts off after 10 minutes.</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td width="24%" bgcolor="#F9F9F9"><p align="left">&nbsp;Voltage:</p></td> 
    <td width="54%" bgcolor="#F9F9F9"><p align="left">&nbsp;220V~50Hz</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Current:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;4.5A </p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Power :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;1000W</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Wind Speed :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;13.5-14m/s</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Body cover :</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Plastic</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Size(mm) : </p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;250x185x100</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Pcs/carton:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;6pcs</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Meas:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;500x430x370</p></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9"><p align="left">&nbsp;</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;Shaver socket:</p></td> 
    <td bgcolor="#F9F9F9"><p align="left">&nbsp;no</p></td> 
  </tr> 
</table> 
<br> 
<p>We are Specialized in manufacturing and exporting sanitary ware series</p>]]></description>
</item>
<item>
<title><![CDATA[Touch-free Hand Dryers YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Touch-free-Hand-Dryers-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:08:17  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Touch-free Hand Dryers YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Touch-free-Hand-Dryers-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:07:53  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Touch-free Hand Dryers YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Touch-free-Hand-Dryers-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:07:30  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Touch-free Hand Dryers YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Touch-free-Hand-Dryers-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:07:04  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Touch-free Hand Dryers YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Touch-free-Hand-Dryers-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:03:58  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Refine Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Refine-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:03:04  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>
to make your hands dryer, so that to reach the requirement of avoiding <BR>
mutual infections.<BR></P>
<BR>
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC">
  <tr>
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td>
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td>
  </tr>
  <tr>
    <td bgcolor="#F9F9F9">&nbsp;</td>
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td>
  </tr>
  <tr>
    <td bgcolor="#F9F9F9">&nbsp;</td>
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td>
  </tr>
  <tr>
    <td bgcolor="#F9F9F9">&nbsp;</td>
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td>
  </tr>
  <tr>
    <td bgcolor="#F9F9F9">&nbsp;</td>
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td>
  </tr>
  <tr>
    <td bgcolor="#F9F9F9">&nbsp;</td>
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td>
  </tr>
  <tr>
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td>
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td>
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td>
    <td bgcolor="#F9F9F9">&nbsp;1650W</td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td>
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td>
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td bgcolor="#F9F9F9">&nbsp;Size:</td>
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td>
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td>
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td>
    <td bgcolor="#F9F9F9">&nbsp;10KG </td>
  </tr>
  <tr>
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td>
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td>
    <td bgcolor="#F9F9F9">&nbsp;11KG </td>
  </tr>
</table>
<br>
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580">
  <tr>
    <td width="189" valign="top"><p>Problem</p></td>
    <td width="190" valign="top"><p>Diagnosis</p></td>
    <td width="190" valign="top"><p>Remedy</p></td>
  </tr>
  <tr>
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td>
    <td width="190" valign="top"><p>Power off</p></td>
    <td width="190" valign="top"><p>Check power</p></td>
  </tr>
  <tr>
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td>
    <td width="190" valign="top"><p>Connect the lead wire</p></td>
  </tr>
  <tr>
    <td width="190" valign="top"><p>Sensor distance too short</p></td>
    <td width="190" valign="top"><p>Adjust sensing distance</p></td>
  </tr>
  <tr>
    <td width="190" valign="top"><p>Sensing device damaged</p></td>
    <td width="190" valign="top"><p>Call service</p></td>
  </tr>
  <tr>
    <td width="189" valign="top"><p>Indicator light off</p></td>
    <td width="190" valign="top"><p>Power off</p></td>
    <td width="190" valign="top"><p>Check power</p></td>
  </tr>
  <tr>
    <td width="189" valign="top"><p>&nbsp;</p></td>
    <td width="190" valign="top"><p>Indicator damaged</p></td>
    <td width="190" valign="top"><p>Call service</p></td>
  </tr>
  <tr>
    <td width="189" valign="top"><p>Not hot air </p></td>
    <td width="190" valign="top"><p>Heater wire broken</p></td>
    <td width="190" valign="top"><p>Call service for replacement</p></td>
  </tr>
  <tr>
    <td width="189" valign="top"><p>Motor not on </p></td>
    <td width="190" valign="top"><p>Motor damaged</p></td>
    <td width="190" valign="top"><p>&nbsp;</p></td>
  </tr>
</table>]]></description>
</item>
<item>
<title><![CDATA[Refine Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Refine-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:02:47  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Refine Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Refine-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:02:28  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Refine Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Refine-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:02:06  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Refine Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Refine-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:01:45  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Fashion Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Fashion-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:01:24  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Fashion Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Fashion-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:01:01  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Fashion Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Fashion-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:00:38  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Fashion Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Fashion-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 15:00:16  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Fashion Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Fashion-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:59:50  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Hotel Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Hotel-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:59:27  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Hotel Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Hotel-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:59:01  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Hotel Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Hotel-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:58:29  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Hotel Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Hotel-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:58:01  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Hotel Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Hotel-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:57:25  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Metal Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Metal-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:57:06  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Metal Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Metal-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:56:44  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Metal Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Metal-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:56:23  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Metal Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Metal-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:55:47  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Metal Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Metal-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:55:23  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Automatic Sensor Hand dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Sensor-Hand-dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:48:15  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Automatic Sensor Hand dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Sensor-Hand-dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:47:45  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Automatic Sensor Hand dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Sensor-Hand-dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:47:26  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Automatic Sensor Hand dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Sensor-Hand-dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:47:03  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Automatic Sensor Hand dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Sensor-Hand-dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:45:23  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Basic Range Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Basic-Range-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:42:22  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Basic Range Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Basic-Range-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:42:00  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Basic Range Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Basic-Range-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:41:40  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Basic Range Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Basic-Range-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:41:17  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Basic Range Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Basic-Range-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:40:55  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Medium Range Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Medium-Range-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:40:32  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Medium Range Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Medium-Range-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:40:11  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Medium Range Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Medium-Range-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:39:42  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Medium Range Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Medium-Range-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:39:21  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Medium Range Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Medium-Range-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:38:18  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Sensor Operated Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Operated-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:35:55  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Sensor Operated Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Operated-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:35:23  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Sensor Operated Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Operated-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:34:53  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Sensor Operated Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Operated-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:34:22  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Sensor Operated Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Operated-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:33:56  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nozzle Activate Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Nozzle-Activate-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:33:34  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nozzle Activate Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Nozzle-Activate-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:33:12  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nozzle Activate Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Nozzle-Activate-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:32:51  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nozzle Activate Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Nozzle-Activate-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:32:26  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nozzle Activate Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Nozzle-Activate-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:32:05  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Washroom Hand Dryers YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Washroom-Hand-Dryers-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:31:41  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Washroom Hand Dryers YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Washroom-Hand-Dryers-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:31:18  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Washroom Hand Dryers YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Washroom-Hand-Dryers-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:30:58  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Washroom Hand Dryers YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Washroom-Hand-Dryers-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:30:17  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Washroom Hand Dryers YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Washroom-Hand-Dryers-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:29:53  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hands Drier YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hands-Drier-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:29:20  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hands Drier YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hands-Drier-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:28:59  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hands Drier YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hands-Drier-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:28:35  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hands Drier YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hands-Drier-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:28:15  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hands Drier YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hands-Drier-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:27:57  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:27:37  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:27:17  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:26:54  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:26:35  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Beautifying Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Beautifying-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:26:14  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Auto Electric Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Electric-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:25:53  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Auto Electric Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Electric-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:25:31  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Auto Electric Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Electric-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:25:12  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Auto Electric Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Electric-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:24:50  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Auto Electric Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Electric-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:24:30  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[High Range Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/High-Range-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:24:07  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[High Range Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/High-Range-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:23:46  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[High Range Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/High-Range-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:23:28  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[High Range Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/High-Range-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:23:02  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[High Range Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/High-Range-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:22:40  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Stainless Steel Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Stainless-Steel-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:18:58  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Stainless Steel Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Stainless-Steel-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:18:39  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Stainless Steel Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Stainless-Steel-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:18:17  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Stainless Steel Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Stainless-Steel-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:17:54  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Stainless Steel Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Stainless-Steel-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:17:30  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Warm Air Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Warm-Air-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:17:09  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Warm Air Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Warm-Air-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:16:48  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Warm Air Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Warm-Air-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:16:23  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Warm Air Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Warm-Air-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:15:55  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Warm Air Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Warm-Air-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:15:19  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Bathroom Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Bathroom-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:14:57  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Bathroom Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Bathroom-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:14:38  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Bathroom Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Bathroom-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:14:14  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Bathroom Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Bathroom-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:13:54  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Bathroom Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Bathroom-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:13:28  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Restroom Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Restroom-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:13:04  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Restroom Hand Dryer]]></title>
<link><![CDATA[http://www.handdryer.cc/Restroom-Hand-Dryer.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:12:34  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Restroom Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Restroom-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:12:10  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Restroom Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Restroom-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:11:48  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Restroom Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Restroom-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:10:56  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Commercial Hand Dryer]]></title>
<link><![CDATA[http://www.handdryer.cc/Commercial-Hand-Dryer.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:10:27  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Commercial Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Commercial-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:10:11  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Commercial Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Commercial-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:09:45  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Commercial Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Commercial-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:09:24  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Commercial Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Commercial-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:09:02  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Air Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Air-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:08:25  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Air Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Air-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:08:03  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Air Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Air-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:07:27  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Air Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Air-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:06:52  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Air Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Air-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:06:30  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Allied Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Allied-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:05:58  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Allied Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Allied-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:05:33  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Allied Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Allied-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:05:13  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Allied Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Allied-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:04:40  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Allied Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Allied-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:04:14  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Super Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Super-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:03:52  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Super Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Super-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:03:30  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Super Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Super-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:03:10  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Super Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Super-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:02:50  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Super Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Super-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:02:29  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Multi Dri Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Multi-Dri-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:02:04  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Multi Dri Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Multi-Dri-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:01:42  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Multi Dri Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Multi-Dri-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:01:19  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Multi Dri Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Multi-Dri-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:00:59  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Multi Dri Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Multi-Dri-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:00:37  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nova Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Nova-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 14:00:09  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nova Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Nova-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:59:44  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nova Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Nova-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:59:23  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nova Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Nova-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:59:03  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Nova Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Nova-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:58:41  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[American Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/American-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:39:29  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[American Hand Dryer]]></title>
<link><![CDATA[http://www.handdryer.cc/American-Hand-Dryer.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:39:04  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[American Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/American-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:38:41  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[American Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/American-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:36:35  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[American Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/American-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:35:52  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Fast Dry Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Fast-Dry-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:34:42  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Fast Dry Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Fast-Dry-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:34:19  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Fast Dry Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Fast-Dry-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:33:44  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Fast Dry Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Fast-Dry-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:32:54  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Fast Dry Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Fast-Dry-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:32:18  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Electric Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Electric-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:31:50  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Electric Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Electric-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:31:17  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Electric Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Electric-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:30:45  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Electric Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Electric-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:30:16  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Electric Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Electric-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 13:29:43  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;260x190x215(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;520x320x240(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Sensor Hand Dryers]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Hand-Dryers.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:16:01  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Sensor Hand Dryers YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Hand-Dryers-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:15:42  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2550W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10.5KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;12KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Sensor Hand Dryers YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Hand-Dryers-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:15:18  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR> 
to make your hands dryer, so that to reach the requirement of avoiding <BR> 
mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1350W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;300x130x230(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;550x380x200(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Sensor Hand Dryers YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Hand-Dryers-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:14:57  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;290x153x216(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;570x360x225(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table> ]]></description>
</item>
<item>
<title><![CDATA[Sensor Hand Dryers YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Sensor-Hand-Dryers-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:14:36  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;260x190x215(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;520x320x240(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[White Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/White-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:14:08  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[White Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/White-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:13:44  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[White Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/White-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:13:21  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[White Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/White-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:12:59  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[White Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/White-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:12:32  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;260x190x215(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;520x320x240(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless High Speed Hand Dryers YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-High-Speed-Hand-Dryers-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:12:04  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless High Speed Hand Dryers YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-High-Speed-Hand-Dryers-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:11:39  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless High Speed Hand Dryers YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-High-Speed-Hand-Dryers-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:11:02  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless High Speed Hand Dryers YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-High-Speed-Hand-Dryers-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:10:36  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless High Speed Hand Dryers YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-High-Speed-Hand-Dryers-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:10:09  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;260x190x215(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;520x320x240(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer No Touch Bobrick YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-No-Touch-Bobrick-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:09:04  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer No Touch Bobrick YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-No-Touch-Bobrick-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:08:40  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer No Touch Bobrick YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-No-Touch-Bobrick-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:08:07  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer No Touch Bobrick YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-No-Touch-Bobrick-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:07:40  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer No Touch Bobrick YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-No-Touch-Bobrick-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:07:14  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;260x190x215(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;520x320x240(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[No Touch Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/No-Touch-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:06:44  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[No Touch Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/No-Touch-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:06:15  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[No Touch Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/No-Touch-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:05:49  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[No Touch Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/No-Touch-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:05:27  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[No Touch Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/No-Touch-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:05:00  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;260x190x215(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;520x320x240(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:04:09  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:03:43  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:03:07  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:02:38  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Automatic Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 11:00:01  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Automatic Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:59:38  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Automatic Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:58:10  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Automatic Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:56:51  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Auto Hand Dryers YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Hand-Dryers-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:54:54  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Auto Hand Dryers YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Hand-Dryers-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:54:07  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Auto Hand Dryers YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Hand-Dryers-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:53:36  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Auto Hand Dryers YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Hand-Dryers-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:53:05  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer YD-254]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-YD-254.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:52:08  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 35 sec ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;2550W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10.5KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;12KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer YD-258]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-YD-258.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:49:10  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer YD-252]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-YD-252.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:48:33  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hands dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1350W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;300x130x230(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;550x380x200(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer YD-251]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-YD-251.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:47:58  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;290x153x216(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;570x360x225(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Touchless Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Touchless-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 10:46:17  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;260x190x215(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;520x320x240(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>
</item>
<item>
<title><![CDATA[Automatic Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Automatic-Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 09:31:02  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table>]]></description>
</item>
<item>
<title><![CDATA[Auto Hand Dryers YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Auto-Hand-Dryers-YD-250.htm]]></link>
<author></author>
<PubDate>Mon, 17 Nov 2008 09:28:29  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P> 
<BR> 
<table width="580" border="0" cellpadding="0" cellspacing="1" bgcolor="#CCCCCC"> 
  <tr> 
    <td width="102" height="20" align="center" bgcolor="#EEEEEE"><strong>Featurers</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp; </td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">3.A light indicates the status of sensor: sensor on, off</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">4. Built-in safety devices turn off the unit when the temperature rises above 65&deg;C due to improper operation</div></td> 
  </tr> 
  <tr> 
    <td bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</div></td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td colspan="2" bgcolor="#F9F9F9"><div style="padding-left:5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</div></td> 
  </tr> 
  <tr> 
    <td height="20" align="center" bgcolor="#EEEEEE"><strong>Specifications</strong> </td> 
    <td colspan="2" bgcolor="#EEEEEE">&nbsp;</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td width="189" bgcolor="#F9F9F9">&nbsp;Voltage:</td> 
    <td width="281" bgcolor="#F9F9F9">&nbsp;AC220V~240V 50Hz</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Rated Power:</td> 
    <td bgcolor="#F9F9F9">&nbsp;1650W</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Wind Speed : </td> 
    <td bgcolor="#F9F9F9">&nbsp;10m/s</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Body cover : </td> 
    <td bgcolor="#F9F9F9">&nbsp;alloy aluminum </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Size:</td> 
    <td bgcolor="#F9F9F9">&nbsp;260x190x215(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;pcs/caron:</td> 
    <td bgcolor="#F9F9F9">&nbsp;2pcs</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;Meas:</td> 
    <td bgcolor="#F9F9F9">&nbsp;520x320x240(mm)</td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;N.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;10KG </td> 
  </tr> 
  <tr> 
    <td height="20" bgcolor="#F9F9F9">&nbsp;</td> 
    <td bgcolor="#F9F9F9">&nbsp;G.W.:</td> 
    <td bgcolor="#F9F9F9">&nbsp;11KG </td> 
  </tr> 
</table> 
<br> 
<table border="1" cellspacing="0" cellpadding="0" align="left" width="580"> 
  <tr> 
    <td width="189" valign="top"><p>Problem</p></td> 
    <td width="190" valign="top"><p>Diagnosis</p></td> 
    <td width="190" valign="top"><p>Remedy</p></td> 
  </tr> 
  <tr> 
    <td width="189" rowspan="4" valign="top"><p>Unit does not operate</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor lead wire loose</p></td> 
    <td width="190" valign="top"><p>Connect the lead wire</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensor distance too short</p></td> 
    <td width="190" valign="top"><p>Adjust sensing distance</p></td> 
  </tr> 
  <tr> 
    <td width="190" valign="top"><p>Sensing device damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Indicator light off</p></td> 
    <td width="190" valign="top"><p>Power off</p></td> 
    <td width="190" valign="top"><p>Check power</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>&nbsp;</p></td> 
    <td width="190" valign="top"><p>Indicator damaged</p></td> 
    <td width="190" valign="top"><p>Call service</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Not hot air </p></td> 
    <td width="190" valign="top"><p>Heater wire broken</p></td> 
    <td width="190" valign="top"><p>Call service for replacement</p></td> 
  </tr> 
  <tr> 
    <td width="189" valign="top"><p>Motor not on </p></td> 
    <td width="190" valign="top"><p>Motor damaged</p></td> 
    <td width="190" valign="top"><p>&nbsp;</p></td> 
  </tr> 
</table>]]></description>
</item>
<item>
<title><![CDATA[Hand Dryer YD-250]]></title>
<link><![CDATA[http://www.handdryer.cc/Hand-Dryer-YD-250.htm]]></link>
<author></author>
<PubDate>Sat, 15 Nov 2008 14:52:19  GMT</PubDate>
<description><![CDATA[<P>Characteristic<BR>Send off suitable hot air automatically when put hands below the nozzle, <BR>to make your hand s dryer, so that to reach the requirement of avoiding <BR>mutual infections.<BR></P><BR>
<TABLE cellSpacing=1 cellPadding=0 width=580 bgColor=#cccccc border=0>
<TBODY>
<TR>
<TD align=middle width=102 bgColor=#eeeeee height=20><STRONG>Featurers</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp; </TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">1.The unit turns on automatically when hands are positioned within 15 cm of the nozzle</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">2.The sensor activates the unit with a 0.5 sec. delay to avoid being turned on mistakenly by unidentified objects passing through</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">3.A light indicates the status of sensor: sensor on, off</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">4. Built-in safety devices turn off the unit when the temperature rises above 65ˇăC due to improper operation</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">5. The unit will cut power off when continuously operated for over 1 min ,to avoid activation by unwanted objects</DIV></TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9 colSpan=2>
<DIV style="PADDING-LEFT: 5px">6. The concentrated air flow will dry hands efficiently within 30-45sec</DIV></TD></TR>
<TR>
<TD align=middle bgColor=#eeeeee height=20><STRONG>Specifications</STRONG> </TD>
<TD bgColor=#eeeeee colSpan=2>&nbsp;</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD width=189 bgColor=#f9f9f9>&nbsp;Voltage:</TD>
<TD width=281 bgColor=#f9f9f9>&nbsp;AC220V~240V 50Hz</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Rated Power:</TD>
<TD bgColor=#f9f9f9>&nbsp;1650W</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Wind Speed : </TD>
<TD bgColor=#f9f9f9>&nbsp;10m/s</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Body cover : </TD>
<TD bgColor=#f9f9f9>&nbsp;alloy aluminum </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Size:</TD>
<TD bgColor=#f9f9f9>&nbsp;260x190x215(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;pcs/caron:</TD>
<TD bgColor=#f9f9f9>&nbsp;2pcs</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;Meas:</TD>
<TD bgColor=#f9f9f9>&nbsp;520x320x240(mm)</TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;N.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;10KG </TD></TR>
<TR>
<TD bgColor=#f9f9f9 height=20>&nbsp;</TD>
<TD bgColor=#f9f9f9>&nbsp;G.W.:</TD>
<TD bgColor=#f9f9f9>&nbsp;11KG </TD></TR></TBODY></TABLE><BR>
<TABLE cellSpacing=0 cellPadding=0 width=580 align=left border=1>
<TBODY>
<TR>
<TD vAlign=top width=189>
<P>Problem</P></TD>
<TD vAlign=top width=190>
<P>Diagnosis</P></TD>
<TD vAlign=top width=190>
<P>Remedy</P></TD></TR>
<TR>
<TD vAlign=top width=189 rowSpan=4>
<P>Unit does not operate</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor lead wire loose</P></TD>
<TD vAlign=top width=190>
<P>Connect the lead wire</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensor distance too short</P></TD>
<TD vAlign=top width=190>
<P>Adjust sensing distance</P></TD></TR>
<TR>
<TD vAlign=top width=190>
<P>Sensing device damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Indicator light off</P></TD>
<TD vAlign=top width=190>
<P>Power off</P></TD>
<TD vAlign=top width=190>
<P>Check power</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>&nbsp;</P></TD>
<TD vAlign=top width=190>
<P>Indicator damaged</P></TD>
<TD vAlign=top width=190>
<P>Call service</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Not hot air </P></TD>
<TD vAlign=top width=190>
<P>Heater wire broken</P></TD>
<TD vAlign=top width=190>
<P>Call service for replacement</P></TD></TR>
<TR>
<TD vAlign=top width=189>
<P>Motor not on </P></TD>
<TD vAlign=top width=190>
<P>Motor damaged</P></TD>
<TD vAlign=top width=190>
<P>&nbsp;</P></TD></TR></TBODY></TABLE>]]></description>